We are moving to a new telephone system. This may cause some initial issues and disruption to calls while it is being set up. If you have any issues, you may wish to call back at another time. We appreciate your patience whilst the new system is implemented and apologise for any disruption that you may experience.
HMO Licensing Standards and Conditions
Introduction
Conditions for licensed Houses in Multiple Occupation (HMOs) are set out in Part 2 of the Housing Act 2004. The Act 2004 also allows councils to apply discretionary conditions to regulate the management, use or occupation of the HMO, its condition and contents. This document explains standards and conditions set by the council for licensed HMOs.
There are 2 different sets of management regulations for HMOs depending on the type of HMO applicable. They are:
The Management of Houses in Multiple Occupation (England) Regulations 2006
This set covers HMOs that contain shared accommodation, such as house shares, bedsits, hostels and guest houses and other non-self contained accommodation. These types of HMOs are defined under Section 254 of the Housing Act 2004.
The Licensing and Management of Houses in Multiple Occupation (Additional Provisions) (England) Regulations 2007
This set covers HMOs that are buildings converted into self contained flats. These types of HMOs are defined under Section 257 of the Housing Act 2004.
All HMOs are subject to the Housing Health and Safety Rating System (HHSRS) which identifies 29 hazards. It is a risk-based evaluation tool used by local authorities for identifying and protecting against potential risks and hazards to health and safety, from any deficiencies present at properties.
The guidance outlined in this document informs conditions, included in property licences, for the Mandatory and Additional Licensing Schemes for HMOs. It is generally expected that this guidance will be followed. There may, however, be exceptional circumstances at a particular HMO that demands a lesser or higher standard.
Failure to comply with any licence condition could result in legal proceedings before a Court, a financial penalty imposed by the council or loss of the licence. In certain circumstances, this may also result in registration on the Government’s database of rogue landlords and property agents under the Housing and Planning Act 2016.
Part 1 - Shared houses
Washing facilities
Bathroom means a room containing a bath or shower.
All bathrooms should:
have their baths, showers and wash hand basins equipped with an adequate supply of cold and constant hot water and be connected to an appropriate drainage system
have their baths, showers and wash hand basins equipped with adequate splashbacks (300mm to baths and wash hand basins, full heights for showers) with an adequate waterproof seal between the splashbacks and the fitting
be of an appropriate size to provide adequate changing and drying space for the users
All water closets (WC) should:
contain awash hand basin equipped with adequate splashbacks and waterproof seal
not open directly onto an area of kitchen where food is prepared unless mechanical extract ventilation and a wash hand basin is provided in the compartment
not normally be more than one floor distant from the sleeping accommodation
All bathrooms and WCs should be:
suitably and adequately heated and ventilated - adequate mechanical ventilation to be in accordance with Approved document F of the Building Regulations 2010. (see heating section in Part 3 – All HMOs)
of an adequate size and layout
provided with suitable floor coverings that are slip resistant, impervious and easily cleansable
conveniently and suitably located in or in relation to the living accommodation in the HMO
Amenity standards in relation to number of persons
Up to 4 occupiers
There should be:
at least 1 bathroom and 1 Water Closet (WC) (the bathroom and WC may be in the same room)
a wash hand basin in the bathroom and in a separate WC (if provided)
5 occupiers
There should be:
1 wash hand basin required where practicable in each sleeping room plus
1 bathroom and
1 separate WC with wash hand basin (but the WC can be contained within a second bathroom)
6 to 8 occupiers
There should be:
1 wash hand basin required where practicable in each sleeping room plus
2 bathrooms with 2 WCs and wash hand basins
9 to 10 occupiers
There should be:
1 wash hand basin required where practicable in each sleeping room plus
2 bathrooms and
2 separate WCs with wash hand basins (but one of the WCs can be contained within one of the bathrooms)
11 to 15 occupiers
There should be:
1 wash hand basin required where practicable in each sleeping room plus
3 bathrooms and
3 separate WCs with wash hand basins (but 2 of the WCs can be contained within 2 of the bathrooms)
Kitchens
Where all or some of the units of accommodation within the HMO do not contain any facilities for the cooking of food there should be a kitchen. This kitchen should:
normally not be more than one floor distant, suitably located in relation to the living accommodation
be of such layout and size and equipped with such facilities so as to safely enable those sharing the facilities to store, prepare and cook food
be provided with suitable floor coverings that are slip resistant, impervious and easily cleansable
have any walls adjacent to cookers, sinks and food preparation areas provided with impervious splash backs
If there are between 10 to 18 occupants a second fully equipped kitchen should be provided. Thereafter there should be a further fully equipped kitchen for up to (and for every) 9 additional occupants.
Any kitchen should be equipped with the following equipment, which should be fit for the purpose and supplied in a sufficient quantity for the number of those sharing facilities:
sinks with draining boards
an adequate supply of cold (from rising main) and constant hot water to each sink
installations or equipment for the cooking of food
electrical sockets
adequate worktops for the preparation of food
cupboards for the storage of food or kitchen and cooking utensils
refrigerators with an adequate freezer compartment (or, where the freezer compartment is not adequate, adequate separate freezer)
appropriate refuse storage and disposal facilities
appropriate extractor fans, fire blankets and fire doors
dining facilities (either within the kitchen or in a separate room on the same storey)
Facility standards
Sinks
minimum standard: A fixed water tight sink and drainer with an adequate supply of cold water and constant hot water
amount needed for:
up to and including 5 persons: 1 sink for up to 5 occupiers
more than 5 and up to 9 persons: 1 sink per 4 occupiers or part thereafter - a dishwasher may be considered as an alternative to an additional sink
Cookers
Installations or equipment for the cooking of food.
minimum standard: The primary facility should comprise an electric or gas hob with 4 rings and an oven with a grill
amount needed for:
up to and including 5 persons: 1 cooker for up to 5 occupiers
more than 5 and up to 9 persons: 1 cooker per 4 occupiers or part thereafter – a microwave oven may be considered as an alternative to an additional cooker
Electrical sockets
minimum standard: 30 amp supply for an electrical cooker. Points should be set at a convenient and safe position
amount needed for:
up to and including 5 persons: 6 sockets (3 doubles). Additional dedicated sockets are required for a cooker, refrigerator and washing machine.
more than 5 and up to 9 persons: An additional double socket for each 2 occupiers over 5 sharing. Additional dedicated sockets are needed for additional cookers, refrigerators and washing machines.
Worktops
For the preparation of food.
minimum standard: the worktops should be secure, fixed and of an impervious material
amount needed for:
up to and including 5 persons: 1500mm (length) x 600mm (depth)
more than 5 and up to 9 persons: Additional 500mm length per user
Cupboards
For the storage of food or kitchen and cooking utensils.
minimum standard: single cupboard (wall or floor mounted) per person. This excludes any cupboard under a sink. Capacity is to be increased proportionately for each additional occupant.
Refrigerators
with an adequate freezer compartment (or, where the freezer compartment is not adequate, adequate separate freezer).
minimum standard: a standard sized combined fridge/freezer.
amount needed for:
up to and including 5 persons: 1 fridge/freezer
more than 5 and up to 9 persons: 2 fridge/freezers
Appropriate refuse disposal facilities
minimum standard: the refuse facilities should not cause problems of hygiene or attract pests and should not obstruct the means of escape in case of fire. A sufficient number of refuse receptacles should be provided for the storage of refuse awaiting collection both internally and externally.
Appropriate extractor fans
minimum standard: electrical extractor fan to be provided in accordance with approved document F under the Building Regulations.
Appropriate fire blankets
minimum standard: to be supplied but not to be sited immediately adjacent to or over a cooker.
Dining space
minimum standard: there should be space to eat meals either within the kitchen or in a separate dining or living room. See room sizes below.
Room sizes
A child (regardless of age) will be considered as a separate occupant in terms of these standards.
The minimum room sizes are also subject to each room being of a shape and floor to ceiling height offering adequate useable living space. In this respect only the floor area where the ceiling is 1.5m or higher will be counted. If there are 10 or more occupiers, additional rooms of the same dimensions are required.
A conservatory will not be counted as a bedroom, lounge, dining room or kitchen.
If there are between 10 to 18 occupants a second fully equipped kitchen should be provided. Thereafter there should be a further fully equipped kitchen for up to (and for every) 9 additional occupants.
Kitchen (without dining space)
Number of occupants
Size (in sq m)
3 to 4
6.5 sq m
5
7 sq m
6
8.5 sq m
7
9 sq m
8
9.5 sq m
9
10 sq m
Kitchen (with dining space)
Number of occupants
Size (in sq m)
3 to 4
11.5 sq m
5
12 sq m
6
13.5 sq m
7
14 sq m
8
14.5 sq m
9
15 sq m
Separate dining room
Number of occupants
Size (in sq m)
3 to 9
10 sq m
10 or more
2 rooms, each 10 sq m
Bedroom - single
Maximum number of occupants
Size (in sq m)
1
6.51 sq m
Bedroom - double
Maximum number of occupants
Size (in sq m)
2
10.22 sq m
Part 2 - Bedsits and non self-contained units
Shared bathrooms
Amenity standards in relation to number of persons
Up to 4 occupiers
There should be:
at least 1 bathroom and 1 Water Closet (WC) (the bathroom and WC may be combined)
a wash hand basin in bathroom and in separate WC (if provided)
5 occupiers
There should be:
1 bathroom and
1 separate WC with wash hand basin (but the WC can be contained within a second bathroom)
Except where a sink is provided - 1 wash hand basin, where practicable, in each unit of living accommodation
6 to 8 occupiers
There should be:
2 bathrooms with WCs and wash hand basins
Except where a sink is provided - 1 wash hand basin, where practicable, in each unit of living accommodation
9 to 10 occupiers
There should be:
2 bathrooms and
2 separate WCs with wash hand basins (but 1 of the WCs can be contained within 1 of the bathrooms)
Except where a sink is provided - 1 wash hand basin, where practicable, in each unit of living accommodation
11 to 15 occupiers
There should be:
3 bathrooms and
3 separate WCs with wash hand basins (but 2 of the WCs can be contained within 2 of the bathrooms)
Except where a sink is provided - 1 wash hand basin, where practicable, in each unit of living accommodation
Individual bathrooms
Where there are no adequate shared washing facilities provided for a unit of living accommodation, an enclosed and adequately laid out and ventilated room with a toilet and bath or fixed shower supplying adequate cold and constant hot water should be provided for the exclusive use of the occupiers of that unit either:
within the living accommodation; or
within reasonable proximity to the living accommodation
These amenities should be located not more than one floor distant from the unit of accommodation.
All bathrooms should:
have baths or showers, and wash hand basins, equipped with taps providing an adequate supply of cold and constant hot water and be connected to an appropriate drainage system
have baths or showers, and wash hand basins, equipped with adequate splashbacks (300mm to baths and wash hand basins, full heights for showers) with an adequate waterproof seal between the splashbacks and the fitting
be suitably and adequately heated and ventilated (see heating section below in Part 3 – All HMOs)
be of an adequate size and layout to provide adequate changing and drying space for the users
be provided with suitable floor coverings that are slip resistant, impervious and easily cleansable
Kitchens
Where a unit of living accommodation contains kitchen facilities for the exclusive use of the individual household, and there are no other kitchen facilities available for that household, that unit should be provided with:
adequate appliances and equipment for the cooking of food
a sink with an adequate supply of cold (from rising main) and constant hot water
a work top for the preparation of food
sufficient electrical sockets
a cupboard for the storage of kitchen utensils and crockery
a refrigerator
a slip resistant, impervious and easily cleansable floor covering, extending 800mm from all units and having an edging strip to secure the edges and to mark the edges of any carpets
appropriate extractor fans and fire blankets
Where kitchens or kitchens with dining facilities in them are shared, the requirements are those listed for kitchens and kitchens with dining facilities in them in Part 1 – Shared Houses.
Facility standards
Sinks
minimum standard: a fixed impervious sink with a drainer. It should be provided with an adequate and wholesome supply of cold water and an adequate supply of constant hot water
amount needed per unit: 1 sink
Cookers
minimum standard: a cooker with at least 2 rings with an oven and a grill. Rings should be at a height level with adjacent worktops
amount needed per unit: 1 cupboard
Electrical sockets
minimum standard: points should be set at a convenient height and safe position
amount needed per unit: 4 sockets (2 doubles). Additional dedicated sockets are required for a cooker and refrigerator
Worktops
For the preparation of food
minimum standard: the worktop should be secure, fixed and of an impervious material
minimum size: 600mm X 1000mm (in useable sections – do not include area underneath microwave or cooker)
Cupboard
For the storage of kitchen utensils and crockery.
minimum standard: standard floor or wall mounted cupboard. The space below the sink unit is not acceptable to comply with this standard.
amount needed per unit: 1 cupboard
Refrigerators
minimum standard: a standard refrigerator with a minimum capacity of 0.15 sq m
amount needed per unit: 1 refrigerator
Room sizes
A child (regardless of age) will be considered as a separate occupant in terms of these standards.
The minimum room sizes are also subject to each room being of a shape and floor to ceiling height offering adequate useable living space. In this respect only the floor area where the ceiling is 1.5m or higher will be counted.
A conservatory will not be counted as a bedroom, lounge, dining room or kitchen.
Bedsit with kitchen in room
Number of occupants
Size (in sq m)
1
13 sq m
2
15 sq m
Bedsit with separate kitchen
Number of occupants
Size (in sq m)
1
10.5 sq m
2
14 sq m
Separate kitchens
Separate kitchens must be at least 4.6 sq m.
Part 3 - All HMOs
Definitions
‘The council’ refers to Brighton and Hove City Council.
‘Licence Holder’ includes any agent or representative acting on behalf of the Licence Holder.
‘HMO’ means House in Multiple Occupation.
‘House’ means the house or flat that is the subject of the licence.
1. References
1.1
The Licence Holder must obtain references for prospective tenants.
1.2
It's understood that in certain situations it may not be possible to obtain a reference. For example, where it's a first tenancy or newcomer to the United Kingdom.
In these situations, you must provide evidence that:
you have explained
the tenant understands the implications of them not adhering to tenancy conditions
The Licence Holder must make a copy of the tenancy agreement available before the House is let so that tenants can read it before being asked to sign.
This also gives tenants an opportunity to get independent advice before signing.
2.3
Copies of the tenancy agreement must be provided for inspection upon demand by the council.
2.4
A copy of the licence and name, address and telephone number (including an emergency contact number) of the Licence Holder or manager must be made available to all tenants.
3. Overcrowding
3.1
The Licence Holder must not allow anyone to live or stay in the HMO if it exceeds a maximum number of persons. The licence will state how many people can occupy the HMO.
Tenants must be informed that they must not allow guests to sleep in their homes, except on an occasional short term basis. If this will exceed the permitted numbers shown on the licence. Short term is deemed as no more than a 2 week period, for when visiting friends or family.
3.2
The Licence Holder may be requested to provide to the council within 28 days of written notice, information below on occupancy at the HMO:
names and numbers of persons and households in occupation, along with confirmation on rooms occupied by them
if required, names and numbers of persons in each household
4. Utility supplies
4.1
The Licence Holder must not unreasonably cause a supply of gas, electricity or water to be interrupted at the HMO.
4.2
The Licence Holder must ensure that the tenant is able to access and obtain readings of all utility meters (gas, electricity or water) for the HMO at reasonable times throughout the tenancy. This includes a final reading at the close of tenancy.
The Licence Holder must supply to the tenant a written document, when the tenancy is signed, describing the locations of utility meters and access arrangements
4.3
The Licence Holder must ensure that the water supply and drainage system serving the HMO is maintained in good, clean and working condition.
5. Gas and carbon monoxide
5.1
If gas is supplied to the HMO, the Licence Holder must arrange for an annual gas safety check, carried out by a Gas Safe registered engineer.
A copy of the current gas safety certificate must be provided to the council at the time of the licence application and annually thereafter.
For annual copies of certificates, they then must be provided within the number of days demanded by the council.
The safety of all gas installations and appliances must be maintained.
5.2
The Licence Holder must ensure a carbon monoxide alarm is installed in any room in the House which is used wholly or partly as living accommodation and contains a fixed combustion appliance other than a gas cooker.
A room includes:
halls
landings
bathrooms/lavatories
If not feasible to install alarms inside bathrooms or lavatories then fit within close distance to those rooms.
5.3
The Licence Holder must ensure that any carbon monoxide alarm installed in any room in the House is kept in proper working order.
5.4
The Licence Holder must supply within 28 days of demand by the council, a declaration by them as to the condition and positioning of any such carbon monoxide alarm or alarms.
6. Fire safety
6.1
The Licence Holder must ensure that smoke alarms are installed on each storey of the House, where there's a room used wholly or partly as living accommodation. A bathroom or lavatory is to be treated as living accommodation.
6.2
The alarms must be kept in proper working order and a declaration as to their condition and position must be provided to the council, on demand, within 28 days.
6.3
Compliance with 6.1 of this licence condition does not mean the House or HMO is subsequently free of any hazard of Fire under the Housing, Health and Safety Rating System.
Further action may have to be taken by the Licence Holder to mitigate this hazard.
6.4
Most HMOs will require a fire detection and alarm system (normally Grade D interlinked or Grade A system) installed in accordance with recommendations of the current British Standard (BS) 5839 Part 6 for domestic premises.
For new installations, a design, installation and commissioning certificate must be provided to the council, on-demand, within 28 days.
6.5
The fire detection and alarm system must be kept in proper working order and maintained and tested in accordance with recommendations of the current BS 5839 Part 6 for domestic premises.
A declaration as to the condition and position of the system, supported by appropriate documentation, must be provided to the council, on-demand, within 28 days.
6.6
Where a Grade A fire alarm and detection and emergency lighting system are installed, the Licence Holder must provide a logbook to the council, on-demand, within 28 days. The logbook must confirm that the system has been maintained correctly.
Annual tests and periodic checks, in accordance with the current BS 5839 Part 6 for domestic premises and BS5266 Part 1 (Emergency Lighting), will provide such confirmation.
6.7
The Licence Holder has a duty to complete and update a fire risk assessment for each House or HMO where there are common areas under the Regulatory Reform (Fire Safety) Order 2005 with additional requirements by the Fire Safety Act 2021 and Fire Safety (England) Regulations 2022.
This legislation is enforced by the East Sussex Fire and Rescue Service. Further information is included at the end of this document.
6.8
The Licence Holder must ensure that any common parts of the House or HMO used as a means of escape from a fire are:
The Licence Holder must ensure that electrical installations in the House are in proper working order and safe for continued use.
7.2
Within 28 days of demand by the council, the Licence Holder must supply a declaration on the safety of electrical installations at the House.
7.3
The fixed electrical wiring and installations:
must be certified as safe by an electrician qualified to complete the test at least every 5 years, unless otherwise indicated on a previous inspection to be sooner
must be in a ‘satisfactory’ condition
The Licence Holder must provide a valid Electrical Installation Condition Report (EICR) based on the current BS 7671 within 3 months from the date of licence issue.
7.4
An electrician is deemed qualified if registered with the:
Electrical Contractors Association (ECA)
National Inspection Council for Electrical Installation Contracting (NICEIC)
National Association of Professional Inspectors and Testers (NAPIT)
The council may accept EICRs from other qualified electricians, provided their competence is proven.
7.5
There must be a minimum of 4 single or 2 double socket outlets in accessible positions in a bedroom or living room.
For numbers of socket outlets in kitchens see the kitchen facilities sections above.
7.6
Upon demand by the council, the Licence Holder must supply a declaration on the safety of electrical appliances, provided as part of the property tenancy at the House.
8. Heating
8.1
Each unit of living accommodation in a House or HMO must be equipped with adequate means of space heating, which should be capable of reaching and maintaining:
21 degrees C in living rooms and bedrooms
22 degrees C in bathrooms
18 degrees C elsewhere
within one hour of being turned on, when the external temperature is minus 1 degree C.
Adequate fixed-space heating is to be provided in every room including bathrooms and (where space allows) kitchens. Paraffin, liquid petroleum gas and free-standing plug-in electric heaters are not considered acceptable in this respect.
The heating should be provided with controls to allow the occupants to regulate the temperature within each individual letting room.
Heating systems should be designed to be of adequate size for the House or HMO.
8.2
Note, compliance with this licence condition does not mean the House or HMO is subsequently free of any hazard of Damp and Mould Growth (heating or insulation) or Excess Cold (heating or insulation) under the Housing, Health and Safety Rating System.
Further action may have to be taken by the Licence Holder to mitigate these hazards.
9. Furniture and furnishings
9.1
The Licence Holder must ensure that furniture and furnishings made available, as part of the property tenancy:
are in a safe condition
comply with current fire safety legislation
This includes all upholstered furniture, covers and fillings of cushions and pillows.
A declaration as to their safety should be made at the time of the licence application. In addition, a declaration must be provided upon demand by the council.
10. Energy efficiency
10.1
Energy Performance Certificates (EPCs) give information on how to keep a property more energy efficient and reduce carbon dioxide emissions.
The Licence Holder shall ensure the House, where required, has a valid EPC. A copy must also be supplied to the tenant or tenants.
The Licence Holder may be requested to provide the council with a copy of the EPC within 28 days of demand.
take all reasonable steps for responding to repair issues at the House
complete repairs within reasonable periods of time
11.2
Specifically, the Licence Holder must:
provide, at the start of every tenancy, clean and in good repair, units of accommodation before tenants move in
continue to keep inside the accommodation in a good state of repair, and where they are responsible for outside of the HMO keep that in repair and ensure the exterior (including boundary walls, fences and gates) is free from graffiti
keep common parts of the House or HMO clean and good decorative repair - in shared houses, it's recognised cleaning shared facilities is usually the tenants’ responsibility but cleaning of communal areas in HMOs occupied as bedsits and flats (where tenants have exclusive rights of occupation for specific parts of the property under separate tenancies) is, however, a landlord’s or manager’s responsibility
where the Licence Holder is responsible for outside of the HMO, ensure that gardens, yards and any external areas in the building’s boundary are kept reasonably clean and tidy and free from rodent infestation
protect and secure the House or HMO within 24 hours of a notification, by completing necessary emergency work (for example, from damage to windows or entrance doors)
12. Property inspections
12.1
The Licence Holder must ensure inspections of the House are completed no less than every 6 months.
Inspections should identify any issues on how the House is managed or its condition.
Records of such inspections must be kept for the duration of the licence.
12.2
In addition, records must show:
who completed inspections
their date and time
issues found
action taken
The Licence Holder may be requested to provide to the council a copy of the records within 28 days of demand.
13. Waste and recycling
13.1
The Licence Holder must comply with the council’s waste collection scheme in place for the storage and disposal of household waste at the House.
Suitable and appropriately sited refuse and recycling containers must be provided. All rubbish containers must have a lid. Recycling containers must have a lid or a net.
All containers should also be kept in a clean and tidy condition and not stored outside the curtilage of the property.
13.2
The Licence Holder must provide new tenants with the information below on waste and recycling:
collection days for refuse and recycling bins from the House
details on what tenants can and cannot recycle
how tenants can dispose of bulky waste and avoid penalties for any fly-tipping
13.3
The Licence Holder must ensure any rubbish or unwanted household items at the end of each tenancy are not left behind.
All items should be removed and disposed of appropriately before the next tenancy starts. This includes any items left:
in front or back gardens or yards
on the pavement in front of the House or HMO
14. Notification of changes
14.1
The Licence Holder must inform the council directly, by email or in writing, on any matter below within 28 days of occurrence:
any change in ownership or management of the House
any change in address, email or telephone number of the Licence Holder or their managing agent
any change to their own or their managing agent’s circumstances which could affect the fit and proper person status of them or that agent
14.2
The Licence Holder must notify the council directly, by email or in writing, of any proposed changes in the construction, layout, fire precautions or amenities at the House. Especially, if this will affect the licence or licence conditions.
Notification should be made at least 28 days before starting work.
14.3
The address of the Licence Holder given on their application form, or a subsequent address provided by them, will be used for the service of any letter, notice or other document between the council and them.
15. Licence limitations
15.1
Transfer of licences
Licences cannot be transferred to:
another person or organisation
a new or different property address
15.2
Companies registered on Companies House
If the Licence Holder is a registered company and is dissolved whilst the licence is in force then the licence ceases to be in force upon that date of dissolution.
15.3
Planning permission
The licence does not grant any planning approvals, consents or permissions, retrospectively or otherwise for the House, under the Town and Country Planning Act 1990 or any related legislation.
15.4
Building Control
The licence does not grant any Building Control (Development Control) approvals, consents or permissions, retrospectively or otherwise for the House.
16. General
16.1
The Licence Holder must arrange for access, to be granted to council officers when requested, at any reasonable time.
They must not prevent council officers from carrying out their statutory duties. This includes inspecting, surveying and investigating the House to ensure compliance with licence conditions.
16.2
The Licence Holder shall ensure that if any alteration or construction works are in progress:
works are completed at the House in such a manner as to ensure the safety of all persons occupying or visiting the property
compliance with Health and Safety legislation is met
16.3
The Licence Holder shall ensure that on completion of any works, the House is left:
If the licensed HMO includes common parts then a Fire Safety Risk Assessment may be required, in accordance with the Regulatory Reform (Fire Safety) Order 2005.
In addition, the Fire Safety Act 2021 and Fire Safety (England) Regulations 2022 clarify what other building elements such as flat entrance doors must be included in Risk Assessments.
To get more information from East Sussex Fire and Rescue Service you can: